CONVERTERS

THE STATIC CONVERTER

A phase converter is a cheap alternative to run 3-phase electric motors when a 3-phase 415-volt mains supply is not available. The converter provides an artificial means by which a 3-phase motor can be operated from a single-phase 240-volt supply.

5 HP Static Unit

STATIC CONVERTERS

HP

kW

Fuse

Cable (mm)

Width

Height

Length

Weight (kg)

1.75

1.3

10A

1.0

12“

8”

12”

9

3.5

2.6

15A

2.5

15“

9”

9”

17

5

3.7

20A

2.5

16“

11”

10”

23

7.5

5.5

25A

4.0

16“

11”

10”

29

10

7.5

30A

6.0

18“

12”

11”

40

12.5

9.3

40A

6.0

18”

12”

11”

44

15

11

50A

10.0

19”

13”

12”

48

Totally Enclosed Rotaries – both the base unit and the motor are housed in a single box.

Rotary Converter HP

Rotary Converter KW

Max Single Motor Capacity HP

Current

Width

Height

Depth

5.5

4

2.75

25A

500mm

500mm

350mm

7.5

5.5

3.75

30A

600mm

600mm

400mm

10

7.5

5

40A

600mm

600mm

400mm

15

11

7.5

50A

750mm

800mm

485mm

20

15

10

60A

750mm

800mm

485mm

 

 


N.B. All converters feature a built-in ammeter enabling the operator to see at a glance the level of the current drawn from the single-phase supply. An output point via a three-phase and earth socket (or three-phase, neutral and earth where applicable) conforming to BS 4343 and rated at either 16A or 32A.